New Boiler? Avoid The Gas Cowbows, Ensure A Perfect Finish!

There is lots to consider when you arestop products of combustion re-entering the
considering a new boiler installation. I hope to takeproperty. If there is no other alternative than to
you through the process from start to finish. Thisput your boiler next to a window that is not in
is quite a difficult task describing in words what Iuse then it will either need blocking up, ie
do everyday. Not all of the points will be relevantcementing and bricking up or it will need screws
to your particular installation but this guide will atput in so that it cannot open. Although the latter
least give you an idea of what to expect frommethod is within the scope of the regulations we
your new boiler and what to expect from anwould recommend the bricking up.
installer coming to your house.Your hot water demand - bathrooms, ensuites
Things to consider:etc
Your budget - grants, loans and other schemesEven the lowest output of boiler (eg a 24KW)
Finding an installer - getting 3 quotescan, if installed correctly, cope with upto 14
The current water pressure of your systemradiators. When determining which boiler will suit
Your current system - layout/design andyour needs you should do some research on
condition, boiler sitingboiler hot water output capacities. Some smaller
Your hot water demand - bathrooms, ensuitesoutput boilers will deliver in the region of say 9
etclitres of water per minute at a certain
Choosing a boilertemperature. Bigger models will produce 16 litres
Upgrading your pipework - gas and waterand more. This difference will be the difference
pipeworkbetween an ok shower or a very powerful
Adding a MagnaCleanshower. It will also affect how long a bath takes
Adding thermostatic radiator valves/roomto fill up. You will also see an impact if you have
thermostattwo bathrooms ie a main bathroom and an
Adding additional radiatorsensuite bathroom. Larger sized boilers will just be
Powerflusing your system or flushing yourable to cope with two showers used
systemsimultaneously. Smaller boilers will definitely not.
Commissioning your systemYou need to consider how this will affect you.
Filling in the benchmark/notifying building controlFurther advice can be given by your chosen
Advising the customer on how to get the bestinstaller.
efficiency from their boilerChoosing a boiler
Installers working to best practiceChoosing a new boiler can be difficult. There are
Your budget - grants, loans and other schemesso many boilers out there that only an expert can
There are lots of schemes available depending onguide you through your needs and match them
your circumstances. The new Boiler Scrappageup with a suitable boiler. The better makes of
Scheme is available to all households in Englandboiler are Viessmann, Worcester and Valliant
who have a G rated boiler in their home. It givesalthough some of the models from these
£400 towards the cost of a new boilermanufacturers have been horrendous. These will
installation. There is also a scheme called thebe the earlier models and any expert will know
Warm Front Scheme which provides uptowhich models to steer well clear of. The
£3500 towards home heating and insulationViessmann 100 model (earlier model) has teething
improvements. To be elible you must be on someproblems but everything has been resolved now
sort of benefit or be a low income household. It isand this is one of the leading models on the
normally a bad idea to finance your boilermarket if not the best. Of course every engineer
installation using a credit card or bank loan.will have his/her own preferences but if you go
Although there are cost benefits to be gained byto any forum in the UK and ask if the Viessmann
having a new condensing boiler these will be eatenboilers are any good I will guarantee you wont
up by repaying the loan. If your current boiler is inget an expert saying anything against them.
good working order and you are worried about itBoilers can typically range in price from £400
breaking down then a British Gas homecare(B&Q) to £1400 (top Vaillant model) Although
agreement is advisable at around £19 perthe £400 one will last for years and years if
month. An Npower agreement which offers lessinstalled properly it is open to debate whether this
benefits is also available at around £7.99 perboiler will last 10 years and even if it does, how
month.much money you will have to spend on repairs?
Finding an installer - getting 3 quotesA great budget boiler is the Glowworm Betacom
You should aim for 3 quotes. This is more than24KW. For the price it represents very good
adequate to get a good idea of what you want.value. It will depend on your budget and what you
Each individual engineer will give you different ideasfeel comfortable. It is always advisable to get
on how best to go forward. They will also havequotes for different boilers and you can see for
their own favourite boilers and methods ofyourself prices differences. The price of the boiler
working. It is a good idea to bounce ideas andwill include all guarantees and if there are any
questions around to ascertain whether theissues with faulty manufacturer parts etc your
engineer is actually competent in the field he willinstaller will be responsible for this. Buying your
be required to work within. Unfortunately thereown boiler and getting an installer to fit it can
are lots of newly qualified plumbers and gaspresent many problems. For example, is the boiler
engineers in this industry and although they areyou are buying relatively new? It may look new,
perfectly safe and 'passed off' to work they mayie unopened packaging etc but it may have been
not be a) able to advise you of the most efficientsitting in a garage for 2 years. If a new boiler is
method going forward, b) advise you completelynot installed within one year of its manufacture
wrongly or c) not actually have an answer.date it will void any warranty. Also, if any
Sometimes it may be difficult to find someonecomponents are missing from your boiler then
you trust; after all, this will be a huge investment.you will be ultimately responsible for lost time and
Often using the yellow pages can be a bad idea.expense. Most installers will not work this way for
So can using someone who posts leaflets throughthe above reasons as they simply do not know
the door. The best and trusted method willthe history of the boiler and if a component fails
always be by personal recommendation. Askingafter the boiler has been fitted it could cause
the engineer lots of questions can also give yousignificant problems.
some degree of confidence. Checking their GasYour installer will match your needs to a suitable
Safe registration should also be a priority.boiler
Unfortunately there are lots of illegal gasUpgrading your pipework - gas and water
engineers operating and these people are puttingpipework
lives at risk. Checking someones gas safeGas pipework used to be run in 15mm from the
registration is very easy. Ask to see a Gas Safemeter to the boiler. There are new rules which
registration card. Every engineer carries a cardmean that pipework must be upgraded to 22mm
and it amazes me that 99.5% of customers doas new condensing boilers are required to run on
not ask for ID. Every engineer should be proud of22mm copper pipework. If the routing is simple
their qualifications and love to show them off. Dothen this can be a simple job. Sometimes carpets
not be shy and in future make a point of it.need to be lifted and pipework will go under
Once you have got your 3 quotes you need tofloorboards. Alot of companies have fixed prices
analyse what you are getting. Quotes should befor pipework alterations and this includes fittings
broken down as much as possible. This will giveto give you an idea of price and labour charges.
you an idea of what exactly you are paying. IAll pipework should be clipped, there are
don't understand how companies can justify listingregulations governing clipping distances for gas
a load of materials and specifications and thenpipework. Pipework should always be secured and
adding a figure. Costs should be fixed price costsmust be sleeved if passing through a cavity wall.
whether you are a millionnaire or on a very lowOne end must be sealed also. Your installer will
budget;)bring you up to speed if you do have any
It is best to get a written contract for your ownconcerns. If you are going from a system boiler
benefit. If the company doesn't offer one thento a combi boiler there will be lots of extra work
you can easily draw one up. This will protectincluding altering pipework and removing tanks and
against faults that might develop later on aftercylinders. This will mean more space in your airing
the system has been installed. If installed to bestcupboard and loft space.
practice and following all manufacturersAdding a MagnaClean
instructions then a central heating system will onlySome companies will not fit and guarantee their
rarely breakdown due to a manufacturerwork if you do not agree to having a MagnaClean
component fault. That is why respected installersfitted. This additional work can be carried out for
offer a personal guarantee on all their work, thisa very reasonable price as they would be already
can be upto 5 years but 3 years is normal. This iscarrying out work in the property. More
alongside normal manufacturer guarantees whichinformation can be found by clicking on the
can be upto 5 years parts and labour. Other waysMagnaClean website. Unfortunately new
of finding an installer can be the internet howevercondensing boiler have very weak heat
personal recommendation is always the bestexchangers and the MagnaClean will save them
method.from getting damaged. This is why most
The current water pressure of your systemcompanies insist on every customer having one
Its very important to measure your mains waterinstalled.
pressure to ascertain whether a combi will actuallyAdding thermostatic radiator valves/room
work. You might not have enough pressure for athermostat
combi system to work so this will need to beAdding thermostatic radiator valves can
measured. A competent engineer will make suresignificantly reduce your heating bills. It allows each
that this is one of the first things he does. If youradiator to be controlled individually. Why have the
do have low pressure then your installationheat on in the whole house when you only need it
options will be limited. One example is when ain one? It is recommend not turning a valve
mains pressure of 0.8bar from a customerscompletely off but setting it to 1. Adding TRV's
property is measured. A certain Vaillant boilerwill in the long run save you lots of money and
which gives their full hot water output at justcan be very cheap to install. Some companies will
0.5bar would be recommended by any competenthave offers when supplying and fitting these.
engineer. This means that this boiler would be oneEnergy efficiency should be promoted whenever.
of a very few boilers that could be considered forA room stat or a programmable room stat is a
this customers property. It could have been alegal requirement. Your installer will advise what
costly mistake not testing the mains waterthe best option for you is. A wireless stat will be
pressure and this is one reason why this shouldmore expensive but there is the advantage of no
be done as standard. Having said all of the above,visible wiring.
problems are very very rare. Your waterAdding additional radiators
company can advise on what your waterIf you need to add additional radiators it is best to
pressure is likely to be if you are concerned. Ifadd these while having a new boiler installed. It will
for say you live on a very big hill you may havemore than likely be cheaper. Some of your
reasons for concern.radiators may be undersized or very old and you
Your current system - layout/design andshould consider upgrading these.
condition, boiler sitingPowerflusing your system or flushing your
Your current situation could have a large affectsystem
on cost of installation. Moving a boiler can addThere is a huge difference between powerflushing
considerable expense as routing pipework canyour central heating system or just flushing your
often be very tricky. Moving a boiler nearer thesystem. Powerflusing involves higher pressure and
gas meter can sometimes cost the same as acirculates fresh water and special chemicals
straight swap. This is because the gas meteraround your system. It is normally needed on
pipework upgrade will require less materials andolder systems as sludge and dirt builds up over
less labour. Although some re-routing of wateryears and years. This will mean that you either
pipes will be required. If you need to upgradehave cold spots or not very hot radiators. Having
from a system to a combi boiler this will be thefresh water in a system means water can be
costliest combi boiler installation. The systemheated up to the maximum pressure the boiler will
layout and pipework will need altering. The hotallow and will mean hotter radiatiors which in turn
water cylinder and tanks in the loft will needmeans more efficiency. A powerflush is not a
removing. If you have a back boiler this will addlegal requirement when replacing your boiler but it
time and expense on aswell. This can sometimesis advisable. When a powerflush is taken with a
be difficult to remove as may cause the chimneyboiler installation discounts can be given.
to weaken. Your installer would be able to adviseNormal cold and hot water flushing is a
whether the removal of the back boiler is bestrequirement when a boiler is installed. Cleanser and
left to a contracted a builder. If there is going toinhibitor is added. A hot and cold flush must be
be new pipework in your property then it isdone in order to work to best practice. New
desirable to have this under the floorboards andboilers do not like any dirt in the system, heat
out of site. It makes for a better, cleaner job.exchangers can get very 'clogged' up and the
Beware of companies wishing to take shortcutscost of replacement can be very great.
or indeed charging more for lifting carpets andCommissioning your system
floorboards. There are strict rules governingThings that should be included in your installation
where pipes are laid in joists. The size of notchesand are considered best practise:
can weaken joists and limits are set for this1. Flushing with Fernox or Sentinel product/filling
reason. It is simply unacceptable to hang pipeswith inhibitor from same
loose - even pipes containing water. Floorboards2. Roomstat/programmer, TRV's (best practise,
should be screwed back into place and not nailedrecommended)
as this will just cause the floorboard to loosen3. Balancing and commissioning according to
over time. Carpets and other fittings should bemanufacturers instructions, important so as not to
left as found. It is normally the customersinvalidate warranty.
responsibility to move furniture and other items4. Decommisioning of old boiler, tanks and all
that are in the way. This is due to responsibilitywaste materials associated with installation
issues. Common sense should always prevail of5. Making good eg. new and old flue openings
course. If you have concrete floors then this can6. Completion of Benchmark log book, important.
add alot of expense as digging into the floor can7. Notification of new boiler to Building Control
be costly. The pipes will then need to be wrapped8. At least 3 years guaranteed on pipework and
to ensure the concrete does not perforate themassociated fitting (the boiler manufacturer will
and this ultimately causes a leak under your floor.have their own guarantees.)
Fixing this leak will mean you having to re-dig theThe above should be in writing to protect your
concrete and replacing the pipework. If doneexpensive new purchase.
correctly and in accordance with manufacturersFilling in the benchmark/notifying building control
instructions its a very simple task. An engineerFilling in the benchmark and notifying building
who is not in the know as regards to regulationscontrol is part of commissioning process and a
can cause severe problems. Boiler siting can alsolegal requirement. Pressures and temperatures
cause problems sometimes. New condensingneed to be taken to ensure the system is
boilers may cause pluming issues and this cancorrectly configured. Not filling out the benchmark
cross neighbour boundaries. Pluming kits areand not notifying building control may cause
available and can eradicate this problem. Boiler flueproblems if you ever decide to sell your property
terminal positions can also be a problem but theseas proof the boiler was installed by a competent
will be rare. The terminal needs to be a minimumperson will be required.
30cm away from window or door openings to